Solvent circulate meter

Table of Contents

What is solvent flow meter?

What is a chemical solvent?

Considerations for selecting a solvent circulate meter

Viscosity considerations and lack of capillary seal

Low lubricity and stress drop

Flow meters for measuring solvents

Turbine flowmeter

Oval gear move meter

Magnetic flowmeter

Gear move meter

Featured merchandise

What is solvent flow meter?

Solvent move meter is a flow meter that measures the volume or mass flow of a solvent. It is very important to accurately measure the quantity of solvent in industrial manufacturing processes. Solvents are divided into organic solvents and inorganic solvents based on their chemical composition. เกจวัดแรงลม are generally used as uncooked materials in varied industries corresponding to coatings, paints and dyes.
Choosing a move meter for chemical service may be difficult. We have to know precisely what the fluid is and the working circumstances. Of specific significance are temperature and line strain. The extra data you give us, the higher we are able to do in deciding on the right circulate meter for your utility.
What is a chemical solvent?

Solvents are substances that can dissolve different solids, liquids, gases and other solutes. The most typical solvent in our day by day life is water. Generally solvents have low boiling points, are risky and cannot react chemically with solutes. Solvents are often colorless and transparent liquids with a particular odor.
Solvents play a vital role in adhesives.
Organic solvents are a large group of natural compounds which might be broadly utilized in life and manufacturing. They have a small molecular weight and are liquid at room temperature. Organic solvents include quite so much of substances similar to paraffins, olefins, alcohols, aldehydes, amines, esters, ethers, ketones, fragrant hydrocarbons, hydrogenated hydrocarbons, terpenes, halogenated hydrocarbons, heterocyclic compounds, nitrogen-containing compounds, sulfur-containing compounds, and so forth. Compounds, etc. Most of them are toxic to humans.
Solvents are usually present in paints, adhesives, varnishes and cleaners. Commonly used organic solvents are DMF, cyclohexanone, acetonitrile, acetic acid, methyl acetate, ethyl acetate, isopropyl alcohol, vinyl acetate, cyclohexane, n-hexane, n-heptane, and so forth.
Organic solvents are a class of organic compounds that may dissolve some substances insoluble in water (such as grease, wax, resin, rubber, dye, and so on.). It is characterized by its liquid state at room temperature and strain. It has larger volatility. During the dissolution process, the properties of solute and solvent stay unchanged.
There are many types of natural solvents, which could be divided into 10 major classes according to their chemical construction.
Aromatic hydrocarbons: benzene, toluene, xylene, and so forth.
Aliphatic hydrocarbons: pentane, hexane, octane, and so on.
Alicyclic hydrocarbons: cyclohexane, cyclohexanone, toluene cyclohexanone, etc.
Halogenated hydrocarbons: chlorobenzene, dichlorobenzene, dichloromethane, etc.
Alcohols: methanol, ethanol, isopropanol, and so forth.
Ethers: ethyl ether, propylene oxide, and so forth.
Esters: methyl acetate, ethyl acetate, propyl acetate, and so forth.
Ketones: acetone, methyl butanone, methyl isobutyl ketone, and so on.
Diol derivatives: ethylene glycol monomethyl ether, ethylene glycol monoethyl ether, ethylene glycol monobutyl ether, and so forth.
Other: acetonitrile, pyridine, phenol, and so on.
Considerations for choosing a solvent flow meter

Don’t simply ask for physique material and anticipate the gauge to work correctly. The body is just a strain vessel containing a working mechanism. The supplies in the body have to be rigorously specified. Always verify the record of materials in the specs. If you experience chemical compatibility problems, will in all probability be within the working mechanism, not in the body.
Do not assume that a plastic-bodied gauge will give you the results you want merely since you are using PVC traces. PVC and CPVC can handle chemical substances that may soften a plastic-bodied gauge in seconds. Plastic body gauges designed for water provide are made of polyacetal and polycarbonate, not PVC. they can’t handle low pH fluids and are topic to solvent attack in some instances.
Viscosity issues and lack of capillary seal

The utility of mechanical instruments requires consideration of fluid properties. Mechanical gauges with oscillating pistons, pendulums (pendulums) or similar measuring parts are known as volumetric gauges. However, what makes it “positive” is the capillary seal between the measuring factor and the sidewall or partaking parts. If you are dealing with low viscosity fluids, i.e. alcohol, toluene, MEK, etc., you lack the viscosity to form a great capillary seal. This will present up as leaks across the measuring factor and can usually trigger the meter to read low.
Low lubricity and strain drop

Positive displacement move meters have surfaces within the measurement chamber which are in contact with each other. In a chapter transferring disc (pendulum), the middle ball rides in a fashioned cup, in an oscillating piston flowmeter, the middle pin is in contact with the roller and the piston diaphragm rides on the hub. This implies that the non-lubricated fluid permits these parts to drag against one another, which increases the frictional load. This loading creates larger pressure drops and will increase wear on the meter.
Flow meters for measuring solvents

The finest method for such fluids is to make use of turbine flow meters. The turbine rotor is suspended by ball or sleeve bearings and has nearly no drag coefficient. This permits turbine move meters to be used for low viscosity in addition to non-lubricated fluids. Another option is the oval gear circulate meter (PD flow meter), which is a constructive displacement device utilizing a double oval rotor. The rotors inherently present a greater seal because their gear design captures a pocket of fluid at the capillary sealing level, thus stopping leakage around the measuring element. Electromagnetic move meters can be used, they usually both enable for extremely correct and efficient solvent move measurement.
Turbine flowmeter

Turbine move meters are velocity flow meters, also called impeller circulate meters. It can be utilized to measure the instantaneous and cumulative circulate rate of solvent liquids. It has the advantages of high accuracy, good repeatability, simple structure, few moving elements, excessive pressure resistance, extensive measuring range, small volume, light weight, small strain loss, simple upkeep, and so forth.
Turbine flowmeter is broadly used for flow measurement: petroleum, chemical business, metallurgy, natural liquid, inorganic liquid, liquefied gasoline, pure gasoline, gas and low temperature fluid. Turbine flowmeter signal may be divided into pulse sign or present signal (4-20mA).
Oval gear move meter

Oval gear flow meter as a mechanical move meter is a standard type of volumetric circulate meter. It can measure the volume move of excessive viscosity and corrosive solvent fluids. It has several benefits.
High measurement accuracy.
Installation piping situations don’t have any impact on the measurement accuracy.
Can be used for top viscosity fluids.
Large vary.
Direct reading meter can get hold of the totalization and whole instantly with out external energy.
Clear and simple to operate.
Magnetic flowmeter

Magnetic circulate meter is a flowmeter that measures the flow of conductive solvent fluids. Abbreviated as EMF, additionally it is referred to as electromagnetic flowmeter. It is a volumetric flow meter. The electromagnetic move meter measures the velocity of a conductive fluid passing through a pipe or conduit. Electromagnetic flowmeter is the best flowmeter selection for the wastewater remedy business.
Gear move meter

The gear flow meter is a miniature digital volumetric circulate meter. Can measure very small flow rates and quantify small volumes of liquid. Resistant to high and low temperatures (-196°C – 200°C).
The gear circulate meter is manufactured from chrome steel and is used for correct continuous or intermittent measurement of the move price or instantaneous move of liquids. It is particularly appropriate for flow measurement of heavy oil, polyvinyl alcohol, grease and different excessive viscosity media. It can measure the viscosity of fluids up to 10,000 Pa.s.
Generally talking, we will select the suitable flowmeter based on the totally different characteristics of chemical solvents. For instance, high viscosity solvents are really helpful to make use of gear circulate meters. For example, for corrosive solvents, electromagnetic flowmeter can be utilized. If you want to scale back the price, you can choose turbine flowmeter.
Of course need to be based mostly on our actual measurement situations, similar to media temperature, pipe temperature, pressure, etc.. Select the appropriate flowmeter to attain accurate measurement.
Featured merchandise

AYT Digital Liquid Magnetic Flow Meter

Learn More AYT Digital Liquid Magnetic Flow Meter

AFT Split Type Electromagnetic Flow Meter

Learn More AFT Split Type Electromagnetic Flow Meter

ACT Insertion Type Magnetic Flowmeter

Learn More ACT Insertion Type Magnetic Flowmeter

LWGY Liquid Turbine Flow Meter

Learn More LWGY Liquid Turbine Flow Meter

AQT Steam Vortex Flow Meter

Learn More AQT Steam Vortex Flow Meter

APT Air Vortex Flow Transmitter

Learn More APT Air Vortex Flow Transmitter

More prolonged reading on circulate meters:
Flow meter vs move transmitter

Select the right irrigation move meter

Electronic move meter

Hot water circulate meter

Chilled water flow meter
Regardless of what, though, do not let anybody make you believe that you aren’t anything but capable when it comes to dealing with #keyword#. This does not necessarily mean that it is going to be easy, and you’re definitely going to need to work for them. If you want to learn more concerning this, the 2 locations which will help you with that are #links# and #links#.


Table of Contents

What is solvent move meter?

What is a chemical solvent?

Considerations for selecting a solvent flow meter

Viscosity considerations and lack of capillary seal

Low lubricity and strain drop

Flow meters for measuring solvents

Turbine flowmeter

Oval gear circulate meter

Magnetic flowmeter

Gear move meter

Featured products

What is solvent circulate meter?

Solvent flow meter is a flow meter that measures the quantity or mass move of a solvent. It is very important to precisely measure the quantity of solvent in industrial production processes. Solvents are divided into organic solvents and inorganic solvents according to their chemical composition. Solvents are commonly used as raw materials in varied industries such as coatings, paints and dyes.
Choosing a move meter for chemical service could be tough. We need to know exactly what the fluid is and the operating conditions. Of explicit importance are temperature and line stress. The extra information you give us, the better we can do in selecting the best move meter for your utility.
What is a chemical solvent?

Solvents are substances that may dissolve other solids, liquids, gases and different solutes. The most common solvent in our every day life is water. Generally solvents have low boiling points, are risky and can’t react chemically with solutes. Solvents are normally colorless and transparent liquids with a particular odor.
Solvents play a vital role in adhesives.
Organic solvents are a large group of natural compounds that are extensively used in life and production. They have a small molecular weight and are liquid at room temperature. Organic solvents embrace a variety of substances such as paraffins, olefins, alcohols, aldehydes, amines, esters, ethers, ketones, aromatic hydrocarbons, hydrogenated hydrocarbons, terpenes, halogenated hydrocarbons, heterocyclic compounds, nitrogen-containing compounds, sulfur-containing compounds, etc. Compounds, and so on. Most of them are toxic to people.
Solvents are often present in paints, adhesives, varnishes and cleaners. Commonly used organic solvents are DMF, cyclohexanone, acetonitrile, acetic acid, methyl acetate, ethyl acetate, isopropyl alcohol, vinyl acetate, cyclohexane, n-hexane, n-heptane, and so on.
Organic solvents are a category of organic compounds that may dissolve some substances insoluble in water (such as grease, wax, resin, rubber, dye, and so forth.). It is characterized by its liquid state at room temperature and stress. It has greater volatility. During the dissolution process, the properties of solute and solvent remain unchanged.
There are many kinds of natural solvents, which can be divided into 10 main classes based on their chemical structure.
Aromatic hydrocarbons: benzene, toluene, xylene, and so on.
Aliphatic hydrocarbons: pentane, hexane, octane, and so on.
Alicyclic hydrocarbons: cyclohexane, cyclohexanone, toluene cyclohexanone, and so on.
Halogenated hydrocarbons: chlorobenzene, dichlorobenzene, dichloromethane, and so on.
Alcohols: methanol, ethanol, isopropanol, and so forth.
Ethers: ethyl ether, propylene oxide, etc.
Esters: methyl acetate, ethyl acetate, propyl acetate, etc.
Ketones: acetone, methyl butanone, methyl isobutyl ketone, and so forth.
Diol derivatives: ethylene glycol monomethyl ether, ethylene glycol monoethyl ether, ethylene glycol monobutyl ether, and so on.
Other: acetonitrile, pyridine, phenol, etc.
Considerations for choosing a solvent flow meter

Don’t just ask for physique material and count on the gauge to work properly. The physique is solely a pressure vessel containing a working mechanism. The supplies in the physique should be fastidiously specified. Always examine the record of supplies within the specs. If you expertise chemical compatibility issues, will in all probability be within the working mechanism, not in the body.
Do not assume that a plastic-bodied gauge will give you the results you want simply because you are using PVC traces. PVC and CPVC can handle chemical substances that may soften a plastic-bodied gauge in seconds. Plastic body gauges designed for water supply are made of polyacetal and polycarbonate, not PVC. they cannot deal with low pH fluids and are subject to solvent assault in some circumstances.
Viscosity issues and lack of capillary seal

The software of mechanical devices requires consideration of fluid properties. Mechanical gauges with oscillating pistons, pendulums (pendulums) or comparable measuring elements are known as volumetric gauges. However, what makes it “positive” is the capillary seal between the measuring component and the sidewall or participating components. If you are coping with low viscosity fluids, i.e. alcohol, toluene, MEK, etc., you lack the viscosity to form a great capillary seal. This will show up as leaks around the measuring factor and can often cause the meter to read low.
Low lubricity and strain drop

Positive displacement flow meters have surfaces in the measurement chamber that are involved with each other. In a chapter transferring disc (pendulum), the middle ball rides in a shaped cup, in an oscillating piston flowmeter, the center pin is involved with the roller and the piston diaphragm rides on the hub. This implies that the non-lubricated fluid allows these elements to pull against one another, which increases the frictional load. This loading creates larger strain drops and increases put on on the meter.
Flow meters for measuring solvents

The finest technique for such fluids is to use turbine flow meters. The turbine rotor is suspended by ball or sleeve bearings and has virtually no drag coefficient. This permits turbine move meters to be used for low viscosity in addition to non-lubricated fluids. Another possibility is the oval gear flow meter (PD circulate meter), which is a positive displacement system using a double oval rotor. The rotors inherently present a greater seal as a result of their gear design captures a pocket of fluid on the capillary sealing point, thus preventing leakage across the measuring element. Electromagnetic circulate meters may also be used, and they both permit for extremely correct and environment friendly solvent circulate measurement.
Turbine flowmeter

Turbine circulate meters are velocity flow meters, also called impeller circulate meters. It can be utilized to measure the instantaneous and cumulative flow price of solvent liquids. It has some nice advantages of excessive accuracy, good repeatability, simple structure, few shifting components, excessive pressure resistance, extensive measuring vary, small volume, gentle weight, small stress loss, easy upkeep, and so on.
Turbine flowmeter is broadly used for circulate measurement: petroleum, chemical trade, metallurgy, natural liquid, inorganic liquid, liquefied gas, pure fuel, fuel and low temperature fluid. Turbine flowmeter signal can be divided into pulse signal or current signal (4-20mA).
Oval gear circulate meter

Oval gear circulate meter as a mechanical move meter is a common kind of volumetric circulate meter. It can measure the volume move of high viscosity and corrosive solvent fluids. It has a quantity of benefits.
High measurement accuracy.
Installation piping conditions don’t have any effect on the measurement accuracy.
Can be used for high viscosity fluids.
Large range.
Direct reading meter can obtain the totalization and whole instantly without exterior power.
Clear and easy to function.
Magnetic flowmeter

Magnetic circulate meter is a flowmeter that measures the circulate of conductive solvent fluids. Abbreviated as EMF, additionally it is known as electromagnetic flowmeter. It is a volumetric circulate meter. The electromagnetic circulate meter measures the rate of a conductive fluid passing through a pipe or conduit. Electromagnetic flowmeter is the best flowmeter selection for the wastewater remedy industry.
Gear flow meter

The gear circulate meter is a miniature digital volumetric circulate meter. Can measure very small flow charges and quantify small volumes of liquid. Resistant to high and low temperatures (-196°C – 200°C).
The gear circulate meter is manufactured from stainless steel and is used for correct steady or intermittent measurement of the circulate fee or instantaneous flow of liquids. It is particularly appropriate for flow measurement of heavy oil, polyvinyl alcohol, grease and different high viscosity media. It can measure the viscosity of fluids up to 10,000 Pa.s.
Generally speaking, we can choose the suitable flowmeter according to the different characteristics of chemical solvents. For instance, high viscosity solvents are recommended to use gear move meters. For example, for corrosive solvents, electromagnetic flowmeter can be utilized. If you have to reduce the cost, you’ll be able to select turbine flowmeter.
Of course have to be based mostly on our actual measurement circumstances, similar to media temperature, pipe temperature, strain, and so forth.. Select the appropriate flowmeter to achieve correct measurement.
Featured merchandise

AYT Digital Liquid Magnetic Flow Meter

Learn More AYT Digital Liquid Magnetic Flow Meter

AFT Split Type Electromagnetic Flow Meter

Learn More AFT Split Type Electromagnetic Flow Meter

ACT Insertion Type Magnetic Flowmeter

Learn More ACT Insertion Type Magnetic Flowmeter

LWGY Liquid Turbine Flow Meter

Learn More LWGY Liquid Turbine Flow Meter

AQT Steam Vortex Flow Meter

Learn More AQT Steam Vortex Flow Meter

APT Air Vortex Flow Transmitter

Learn More APT Air Vortex Flow Transmitter

More extended studying on circulate meters:
Flow meter vs move transmitter

Select the right irrigation flow meter

Electronic move meter

Hot water flow meter

Chilled water flow meter

Leave a Comment