Signal clamping in pressure transmitters

In certain applications, the existing or voltage signal of a pressure transmitter should never exceed and/or drop below a critical value. This could be ensured using so-called signal limiting.
Why is a signal clamping necessary in the first place?
If the pressure on a pressure transmitter lies within the nominal pressure range, then you will see a precise signal output (e.g. 4 ? 20 mA or 0 ? 10 V). However, in technical applications, it frequently happens that an originally planned pressure range is exceeded or is dropped below. This can happen deliberately, for instance when cleaning, and also accidentally, for example through load variations or in case of a fault. In เกจไนโตรเจนsumo , the sensor signal will also move outside the defined limits, so that, for example, a current signal in the range of 3.6 to 25 mA may appear.
If now, however, the evaluation electronics are set so that they recognise a signal outside of the defined limits being an error, in some situations, trouble-free operation of the complete system cannot be ensured anymore. In such cases, a sign limiting of the pressure transmitter makes sense, so that the output signal is maintained within the required range (e.g. 3.8 ? 21 mA).
Note
A good example of a pressure transmitter with that your voltage signal as well as the current signal can be limited is the model S-20 (for general industrial applications) or the model MH-3 (for mobile working machines) from WIKA.