NAFFCO, the world’s leading producer and supplier of life safety solutions exhibits at Intersec 2017, the world’s largest and most complete trade and networking exhibition for the Security and Safety industries.
A leading producer and supplier of life safety options, NAFFCO, the founding sponsor of Intersec is presenting the most recent merchandise and trends in security and safety specializing in its good applied sciences and improvements. Intersec 2017 is being held from twenty second to 24th January on the Dubai International Convention and Exhibition Centre, Dubai, UAE.
Recognizing Intersec as an international assembly platform, Eng. Khalid Al Khatib, Chief Executive Officer mentioned, “NAFFCO shall be standing out as a “one-stop-solution” supply for every type of fire protection systems. In the 1,439-sqm stand at Hall 6 of the Dubai World Trade Center, NAFFCO will showcase its wide range of state-of-the-art firefighting merchandise including heavy-duty hearth hoses and reels, fireplace suppression and protection techniques, custom-made fire cabinets, extinguishers, fire pumps fire-rated doors, fire alarms, CCTV systems, ambulances, rescue automobiles and hearth vehicles as well as cellular hospitals and platform vehicles.”
In this year’s edition, NAFFCO highlighted, among other improvements and services, the newly launched Pump Cloud, NAFFCO Automatic Fuel Filtration System, Aircraft Rescue Firefighting Vehicle (ARFFV), Emergency Lighting System, NAFFCO Training, New Eco-barid foam extinguisher for lithium batteries – a new type of specialist fireplace extinguisher to be used on class D fires; SIL2 etc
Pump Cloud:
Considering the necessary role of fire pump as the center of firefighting system, it must be monitored round the clock to make certain that it is correctly working particularly throughout emergencies. Pump Cloud is a contemporary and progressive system that enables 24/7 monitoring of fireplace pumps. It uses an interface unit connected with the fire pump controllers and associated sensors and equipment in the Fire Pump room which in flip will send monitored indicators to a special modem that communicates with NAFFCO Desktop Managing system by way of 3G or GPRS, where NAFFCO upkeep staff on standby are monitoring the pump 24 / 7 and prepared for action.
NAFFCO Automatic Fuel Filtration System:
Fuel contamination is a significant explanation for premature shutdown for standby engines, generator sets, hearth pump engines, and other diesel engine support capabilities. Contamination starts as soon because the tanks are stuffed and continues till the fuel is used. As the length of storage period is increased, the likelihood of untimely engine shutdown is also increased because of clogged filter or excessive water entrainment.
The solution: NAFFCO Automatic Fuel Filtration System. It is a self-contained, stand-alone system that removes and prevents the build-up of water, sludge and contaminants in tanks. It stabilizes diesel and bio-fuels, eliminates microbial contamination to optimize and keep gasoline high quality. It is designed to meet NFPA requirements in maintaining and cleansing gas stored in fuel tanks in accordance with NFPA 20, NFPA 25, and NFPA 110.
Aircraft Rescue Firefighting Vehicle (ARFFV):
Also known as the Fire Falcon 6, ARFFV is again in the Intersec this year proudly showcasing its personal manufactured prototype of the falcon cabin which was successfully tested as per the internationally acknowledged testing E/ECE/324 and E/ECE/TRANS/505, Addendum 28, Regulation No. 29 with regard to protection of the occupants of the cabin. In the continuous effort to offer NAFFCO customers with proven and secure applied sciences, the requirements of the standard were purposely exceeded and the falcon cabin demonstrated excellent strength and impression properties. The roof power was examined with 13500 kg, which is 3500kg greater than the regulation requirement and the front impression test was carried out at 55 kJ, against the forty five kJ specified by the regulation.
Emergency Lighting System:
When the final synthetic lighting fails, orientation must nonetheless be ensured in buildings even for visitors. Accordingly, there are เกจวัดแรงดันลม10bar governing the tools and dimensioning of emergency lighting installations that shall be activated when there is no mains voltage.
NAFFCO Provides the Intelligent Emergency Lighting Solution that ensures the security and integrity of your emergency system with automated monitoring and reporting resolution. All the products Control Panel, Emergency Luminaires and equipment are fully tested and authorized by British Standards Institution (BSI).
Easy Addressing & Grouping of Lights, Sets Maintenance Schedule, Generates auto Reports by using NAFFCO Addressable Emergency lighting monitoring contact panel. NAFFCO Emergency and Exit Lights are designed with newest LED expertise which is absolutely complying with green constructing idea.
Eco Barid Foam Fire Extinguisher for Class ABD and F
NAFFCO saved pressure kind Eco Barid foam extinguisher are multipurpose, perfect for fires involving risky liquids and freely burning material similar to paper, cloth, wood, furniture and cooking oil or fats fires (A,B,D and F classes of fire) and is appropriate for the use with most kinds of proportioning and discharge devices which performs excellently when used with CAF systems. ECO BARID FOAM is one hundred pc environmental friendly free from PFOA, PFOs and fluorine.
It is designed for rapid hearth knockdown by creating a movie on the object of fireplace and along with this, it creates a cooling effect and acts like a fireplace sealant which helps to extinguish the hearth faster and minimize re ignition. The environmental pleasant elements in the foam concentrate have the deep impregnation capability when used on flamable stable materials fires which makes it close to to unimaginable for re ignition. This is necessary when extinguishing deep-seated fires in wood, paper, rubber, and other ordinary combustibles. It acts like a fire sealant when applied on combustible materials.
SIL2
Safety Integrity Level (SIL2) is a measure of the reliability of a system to be in operation when a maximum risk and fault are analysed based mostly on no of flooring, occupancy and in accordance to the guide lines set by the Engineer or the Authority having Jurisdiction to maximise the reliability and effectivity of Life Safety, that’s the place you will want a SIL2 rated panel.
Why SIL2 supersedes the Normal Addressable Fire Alarm Panel?
Redundancy: CPU, I/O playing cards, Power Supply and Display out there on the panel to make sure the continual operation incase of one or more failures.
Hot–swap: CPU, I/O cards, Power Supply and Display could be changed without switching off the panel, thus sustaining system safety and security functionality.
Extreme discount of false alarms below acceptable levels out of 100 indicators there’s a risk for only one fault.
High degree of Reliability, Availability and Maintainability (RAM) for the software program and hardware of the system.
High tolerance and stability over electromagnetic noise.
NAFFCO Training
To enhance consciousness and alleviate technical information on hearth security requirements, NAFFCO presents coaching programs based mostly on 3 major aspects specifically:
Theory. Using the classroom environment our internationally accredited instructors teach NFPA guidelines and laws.
Practical. We offer hands-on training on all fireplace security systems
Testing and certification. We provide NFPA certifications in addition to NAFFCO certifications
For extra information please visit www.naffco.com
Share