Mechanical pressure switches: How does one set the switch point?

Mechanical pressure switches are often given a factory-set switch point. Nevertheless, some users want to make this configuration themselves, as, for example, the pressure conditions in the application form can change. Regarding pressure switches with a measuring element in a bellows, diaphragm or piston design, the manual setting of the switch point, reset point or hysteresis (according to the model) requires a specific amount of effort. But it?s not witchcraft. This short article explains, step by step, how to take action.
Users need the next equipment: a pressure source (e.g. a dead-weight tester), a control pressure gauge, a continuity tester or perhaps a control lamp in addition to a tool for the adjustment screw (by the way, WIKA supplies the correct Allen key with its instruments; a conventional screwdriver is enough for setting the hysteresis).
Setting plan view for the model PSM02 mechanical pressure switch from WIKA. The pin assignment 1 and 3 (small picture) corresponds to the switching function ?normally closed?, the assignment 2 and 3 will be for ?normally open?.
Setting of the switch point
First, screw the pressure switch into the pressure source connection and connect its electrical connections to the continuity tester or control lamp.
Turn the adjustment screw for the switch point in completely. This sets the switch point to the highest possible value.
Now apply the required switching pressure to the pressure switch before control pressure gauge indicates the value.
From then on, turn the adjustment screw out until the instrument switches and the continuity tester or the control lamp reacts.
Then lower the pressure until the pressure switch switches back and then increase it again to check on the switch point. If necessary, the switch point must be corrected by turning the adjustment screw. Repeat the procedure until the desired switch point is reached.
Setting of the reset point
In a few applications, the reset point is set rather than the switch point, e.g. for minimum pressure monitoring. Here the task is similar to the switch point, but without turning in the adjustment screw.
Increase the pressure before instrument switches.
Then lower the pressure until the instrument switches back and adjust the positioning of the adjustment screw accordingly. The guideline here is:
Set point < Actual value: Turn the screw out
Set point > Actual value: Turn the screw in
Setting of the hysteresis (not with all models)
To do this, first set the switch point and then check the reset point (see above). Depending on the reset point, the hysteresis screw is turned in or out. The switch point must then be checked, as changes to the hysteresis screw also affect the switch point.
Note
An overview of the many mechanical pressure switches and further technical information can be found on the WIKA website. Should you have any questions, your contact will gladly assist you to.
Also read Pus : Functionality
Mechanical vs electronic pressure switches: Application areas
Pressure switches in booster pumps
SIL pressure switch: Safety in tyre manufacturing